GTF, ltd

Borehole Electric Pump Units



Borehole Electric Pump Units I

Purpose: Borehole electric pump units I are designed for delivering water from boreholes at temperature up to 25 °С, with general mineralization not more than 1500 мg/l containing hard mechanical impurities not more than 0,01 %, the contents of chlorides not more than 350 мg/l, sulphites not more than 500 мg/l, hydrogen sulphite — not more than 1,5 мg/l. They are applied in urban, industrial and agricultural water-supply.

Pump type Dilivery
м3/h
Head pressure,
m
Power of the electric motor,
kW
Pump/unit weight,
kg
Resource till
capital repairs,
hour
ЭЦВ4-1,5-50 1,5 50 0,6 17 12500
1ЭЦВ6-4-130...190 4 130...190 4,5 74...88 16000
ЭЦВ6-10-50...235 10 50...235 2,8 ... 11 73...120 16000
ЭЦВ6-6,5-90..250 6,5 90...250 2,8 ... 8 70...107 16000
ЭЦВ6-16-75...160 16 75...160 5,5 ... 11 77...124 16000
ЭЦВ8-16-140...200 16 140...200 11...16 140...167 17000
ЭЦВ8-25-110...145 25 110...145 11...16 140...160 17000
ЭЦВ8-40-60...90 40 60...90 11...16 139...167 17000
ЭЦВ10-120-60..120 120 60...120 32...65 270...443 18000
ЭЦВ10-63-65...270 63 65...270 22...65 200...420 18000
ЭЦВ12-160-65..100 160 65...100 45...65 280...415 18000

TOP


Borehole Electric Pump Units II

Purpose: Borehole electric pump units II are designed for evacuating ground seam chemically-active water with total mineralization not more than 2200 мg/l at temperature up to 25 °С and containing hard mechanical impurities not more than 0,01 %, the contents of chlorides not more than 400 мg/l, sulphites — not more than 600 мg/l, hydrogen sulphite — not more than 1,5 мg/l.

Pump type Dilivery
м3/h
Head pressure,
m
Power of the electric motor,
kW
Pump/unit weight,
kg
Resource till
capital repairs,
hour
1ЭЦВ14-210-300Х 210 300 250 1610 12500
1ЭЦВ16-375-175Х 375 175 250 1480 12500

TOP


Borehole Electric Pump Units of Special Design

Purpose: Borehole electric pump units of special design are intended for evacuating ground waters with general mineralization not more than 25000 мg/l at temperature up to 25 °С and containing hard mechanical impurities not more than 0,05 %, the contents of chlorides not more than 350 мg/l, sulphites — not more than 500 мg/l, hydrogen sulphite — not more than 1,5 мg/l.

Pump type Dilivery
м3/h
Head pressure,
m
Power of the electric motor,
kW
Pump/unit weight,
kg
Resource till
capital repairs,
hour
2ЭЦВ10-160-35Г 160 35 22 210 16000
3ЭЦВ12-255-30Г 255 30 32 254 16000
ЭЦВ12-160-100ХТр 160 100 65 484 12500

TOP



GO HOME

E-mail: gtf@pump.freeservers.com