Purpose: Borehole electric pump units I are designed for delivering water from boreholes at temperature up to 25 °С, with general mineralization not more than 1500 мg/l containing hard mechanical impurities not more than 0,01 %, the contents of chlorides not more than 350 мg/l, sulphites not more than 500 мg/l, hydrogen sulphite — not more than 1,5 мg/l. They are applied in urban, industrial and agricultural water-supply.
Pump type | Dilivery м3/h |
Head pressure, m |
Power of the electric motor, kW |
Pump/unit weight, kg |
Resource till capital repairs, hour |
---|---|---|---|---|---|
ЭЦВ4-1,5-50 | 1,5 | 50 | 0,6 | 17 | 12500 |
1ЭЦВ6-4-130...190 | 4 | 130...190 | 4,5 | 74...88 | 16000 |
ЭЦВ6-10-50...235 | 10 | 50...235 | 2,8 ... 11 | 73...120 | 16000 |
ЭЦВ6-6,5-90..250 | 6,5 | 90...250 | 2,8 ... 8 | 70...107 | 16000 |
ЭЦВ6-16-75...160 | 16 | 75...160 | 5,5 ... 11 | 77...124 | 16000 |
ЭЦВ8-16-140...200 | 16 | 140...200 | 11...16 | 140...167 | 17000 |
ЭЦВ8-25-110...145 | 25 | 110...145 | 11...16 | 140...160 | 17000 |
ЭЦВ8-40-60...90 | 40 | 60...90 | 11...16 | 139...167 | 17000 |
ЭЦВ10-120-60..120 | 120 | 60...120 | 32...65 | 270...443 | 18000 |
ЭЦВ10-63-65...270 | 63 | 65...270 | 22...65 | 200...420 | 18000 |
ЭЦВ12-160-65..100 | 160 | 65...100 | 45...65 | 280...415 | 18000 |
Purpose: Borehole electric pump units II are designed for evacuating ground seam chemically-active water with total mineralization not more than 2200 мg/l at temperature up to 25 °С and containing hard mechanical impurities not more than 0,01 %, the contents of chlorides not more than 400 мg/l, sulphites — not more than 600 мg/l, hydrogen sulphite — not more than 1,5 мg/l.
Pump type | Dilivery м3/h |
Head pressure, m |
Power of the electric motor, kW |
Pump/unit weight, kg |
Resource till capital repairs, hour |
---|---|---|---|---|---|
1ЭЦВ14-210-300Х | 210 | 300 | 250 | 1610 | 12500 |
1ЭЦВ16-375-175Х | 375 | 175 | 250 | 1480 | 12500 |
Purpose: Borehole electric pump units of special design are intended for evacuating ground waters with general mineralization not more than 25000 мg/l at temperature up to 25 °С and containing hard mechanical impurities not more than 0,05 %, the contents of chlorides not more than 350 мg/l, sulphites — not more than 500 мg/l, hydrogen sulphite — not more than 1,5 мg/l.
Pump type | Dilivery м3/h |
Head pressure, m |
Power of the electric motor, kW |
Pump/unit weight, kg |
Resource till capital repairs, hour |
---|---|---|---|---|---|
2ЭЦВ10-160-35Г | 160 | 35 | 22 | 210 | 16000 |
3ЭЦВ12-255-30Г | 255 | 30 | 32 | 254 | 16000 |
ЭЦВ12-160-100ХТр | 160 | 100 | 65 | 484 | 12500 |